Delhi
+919811236960

'work place safety'

Items tagged with 'work place safety'

product image
PCR WORK STATION

Working table of S.S. 304 Body is made of Wooden/ M.S. Duly Powder Coated/ S.S. 304 Imported Mini Pleat HEPA Filter of 0.3μ of an efficiency of 99.97% down to 0.3μ media is of glass fiber & made of pleats back & frown in a anodized Aluminum frame. Pre filter of dry fiber washable type with the frame of on all the sides. Confirm the international standards 209 E. Class 100 (As per USFED-STD. 209E) ISO Class 5 (As per ISO-14644.1), IEC 61010-1:2010, ISO 29463-5:2022 Statically Balanced motor blower Assembly (Heavy Duty) Velocity at the output of HEPA is 90 ± 20 FPM Noise level is very low Vibration is also very low. Normal working fluorescent Light. Static pressure Manometer U. V. Light 1 x 30/15 watts. Front Door of Acrylic Sheet (Transparent) Or any non standard size Optional: Magnahelic Gauge in place of Static Pressure Manometer. Digital Manometer U.V. Resistant Poly Carbonate sheet in place of Acrylic Sheet. Automatic Safety system for U.V. light. Automatic start system filtered Air & Normal light in Laminar Air Flow LCD display with soft touch switches for Motor, U.V. Light, F.V. Light & U.V. Timer Automatic motorised front door lifting arrangement Online transfer of data without any cable/wire Interference

Send Message
product image
BIOSAFETY CABINET CLASS III

“OPTICS TECHNOLOGY” Class III Bio safety cabinet offers the highest level of operator, product and environmental protection from infectious/biohazardous aerosols and is suitable for microbiological work. Designed for an absolute level of containment, it is frequently used for work involving the deadliest bio-hazards. A Class III cabinet is defined as a totally enclosed, ventilated cabinet with leak-tight construction it is also called glove boxes. The cabinet is maintained under negative pressure and supply air is drawn in through HEPA filters. A supply of HEPA filtered air provides product protection and prevents cross contamination of samples while exhaust air is HEPA-filtered and incinerated. Key Benefits: Safer dual main with 100% exhaust filters Exclusive dual main exhaust filters provide > 100.000 times better protection than single-stage designs. An integrated pass-through with interlocking doors permits materials transfer without risk of environmental contamination. An angled cabinet front ensures a comfortable working posture. Energy Efficient Blowers Optional: 1. Magnahelic Gauge in place of Static Pressure Manometer. 2. Digital Manometer 3. U.V. Resistant Poly Carbonate sheet in place of Acrylic Sheet. 4. LCD display with soft touch switches for Motor, U.V. Light, F.V. Light & U.V. Timer 5. Imported Gloves 6. Automatic motorised front door lifting arrangement 7. Online transfer of data without any cable/wire Interference MICROPROCESSOR BASED TOUCH SCREEN DISPLAY SYSTEM Display of velocity with lower and upper safe limits. Display of total run time of instrument & timer for U.V. lamp Control of U.V. light to prevent the operator from U.V. rays as and when required. Automatic Door sensors to switch off the U.V. light when door is opened. Display of message for life of HEPA filter, U.V. light etc. With Glove Port (Without Gloves) Outer Body: Wooden / Mild Steel Duly Powder Coated / Stainless Steel (S.S. 304)

Send Message
product image
BIOSAFETY CABINET CLASS II

Applications include isolation and indentification of plant/human pathogens, work in virology, tissue culture, sterility testing and recombinant DNA research. This Biohazard Cabinet offers operator protection from low to moderate risk biological agents (or chemical carcinogens), while providing a sterile work environment for the procedure. The cabinet is kept under negative pressure with partial quantity of recirculated air exhausted through a HEPA filter. External exhaust from the laboratory is optional. The Biological Safety Cabinet is similar in performance and specification to the Vertical Series, described on reserse. The additional main features are as under:- Specially suited for Pathogenic work, chemical work, critical biological work involging virus and pathogens & for microbiology, biochemistry etc. Standard S.S. Perforated table. Imported Mini Pleat HEPA of 0.3 µ of an efficiency of 99.97% down to 0.3 micron Media is of glass fiber & made of pleats back & fro in an anodized aluminum frame (With Test Report). Integral powerful exhaust system. Built-in-positive Air Curtain effect to prevent inside air from going out and room air from entering in, providing total process and operator safety. Exhaust ducting to carry the air outside. Front sliding door, U.V. light, Manometer, Gas cock etc. Mini Pleat HEPA Filter in Exhaust. Virus Burn out Unit in Exhaust. FACE VELOCITY: A face velocity of 90±20 FPM is maintained. Optional: Magnahelic Gauge in place of Static Pressure Manometer. Digital Manometer U.V. Resistant Poly Carbonate sheet in place of Acrylic Sheet. LCD display with soft touch switches for Motor, U.V. Light, F.V. Light & U.V. Timer Gloves Port (Without Gloves) Automatic motorised front door lifting arrangement Online transfer of data without any cable/wire Interference MICROPROCESSOR BASED TOUCH SCREEN DISPLAY SYSTEM Display of velocity with lower and upper safe limits. Display of total run time of instrument & timer for U.V. lamp. Control of U.V. light to prevent the operator from U.V. rays as and when required. Automatic Door sensors to switch off the U.V. light when door is opened. Display of message for life of HEPA filter, U.V. light etc.

Send Message
product image

Air Flow: Vertical With Working table of S. S. 304 Body is made of Wooden/ M.S. Duly Powder Coated/ S.S. 304 Imported Mini Pleat HEPA Filter of 0.3µ of an efficiency of 99.97% down to 0.3µ media is of glass fiber & made of pleats back & frown in a anodized Aluminum frame. Prefilter of dry fiber washable type with the frame of on all the sides Confirm the international standards 209 E. Class 100 (As per USFED-STD. 209E) ISO Class 5 (As per ISO-14644.1), IEC 61010-1:2010, ISO 29463-5:2022 Statically Balanced motor blower Assembly (Heavy Duty) Velocity at the output of HEPA is 90 ± 20 FPM Noise level is very low Vibration is also very low Normal working fluorescent Light Static pressure Manometer U. V. Light 1 x 30/15 watts Front Door of Acrylic Sheet (Transparent) Gas cock Or any non standard size Optional: Magnahelic Gauge in place of Static Pressure Manometer. Digital Manometer U.V. Resistant Poly Carbonate sheet in place of Acrylic Sheet. Automatic Safety system for U.V. light. Automatic start system filtered Air & Normal light in Laminar Air Flow LCD display with soft touch switches for Motor, U.V. Light, F.V. Light & U.V. Timer Automatic motorised front door lifting arrangement Online transfer of data without any cable/wire Interference MICROPROCESSOR BASED TOUCH SCREEN DISPLAY SYSTEM Display of velocity with lower and upper safe limits. Display of total run time of instrument & timer for U.V. lamp Control of U.V. light to prevent the operator from U.V. rays as and when required. Automatic Door sensors to switch off the U.V. light when door is opened. Display of message for life of HEPA filter, U.V. light etc.

Send Message
product image
MANUAL HYDRAULIC PALLET PRESS

“Optics Technology” manually operated Hydraulic Pallet Press for fast and easy preparation of both solid and highly permeable pellet. Working: The pressure pallet and die arm are located in inner cylinder sample is placed in between polished pressure plates. A Hydraulic Press is then used to apply necessary pressure to the sample via die. Cylinder Type : Single acting, up stroking Weight : 35 kgs Pump Type : Hand Operated Safety Feature : Pressure relief valve to safeguard against applying over-pressure Model Size OT-MHPP-276/10 10mm KBr Die Set (Stainless Steel) OT-MHPP-276/13 13mm KBr Die Set (Stainless Steel)

Send Message
product image
HYDROTHERMAL AUTOCLAVE

Features: Good corrosion resistance, non-spill of hazardous substances, reduce pollution, safety for use. Containing Teflon bushing, double care so that the raw material could be acid, alkali, and many more. • It can replace the platinum crucible to solve the analysis of trace elements in high purity alumina dissolving deal with problems. Poperties: • Shell made of high-quality stainless steel (S.S. 316) with Inner PTFE (Teflon Liner) Chamber • Maximum Operating Temperature: - 220°C Working Pressure : ≤ 3MPa OR 30 Bar • Safe Temperature : 200°C • Heating and Cooling Rate : ≤5°C/min Model Capacity OT-HAU-332-A 10ml OT-HAU-332-B 25ml OT-HAU-332-C 50ml OT-HAU-332-D 100ml OT-HAU-332-E 150ml OT-HAU-332-F 200ml OT-HAU-332-G 250ml OT-HAU-332-H 300ml OT-HAU-332-1 400ml OT-HAU-332-J 500ml OT-HAU-332-K 1000ml OT-HAU-332-L 1500ml OT-HAU-332-M 200ml

Send Message

Still searching for
work place safety?