Delhi
+919811236960

'total run time'

Items tagged with 'total run time'

product image

Air Flow: Vertical With Working table of S. S. 304 Body is made of Wooden/ M.S. Duly Powder Coated/ S.S. 304 Imported Mini Pleat HEPA Filter of 0.3µ of an efficiency of 99.97% down to 0.3µ media is of glass fiber & made of pleats back & frown in a anodized Aluminum frame. Prefilter of dry fiber washable type with the frame of on all the sides Confirm the international standards 209 E. Class 100 (As per USFED-STD. 209E) ISO Class 5 (As per ISO-14644.1), IEC 61010-1:2010, ISO 29463-5:2022 Statically Balanced motor blower Assembly (Heavy Duty) Velocity at the output of HEPA is 90 ± 20 FPM Noise level is very low Vibration is also very low Normal working fluorescent Light Static pressure Manometer U. V. Light 1 x 30/15 watts Front Door of Acrylic Sheet (Transparent) Gas cock Or any non standard size Optional: Magnahelic Gauge in place of Static Pressure Manometer. Digital Manometer U.V. Resistant Poly Carbonate sheet in place of Acrylic Sheet. Automatic Safety system for U.V. light. Automatic start system filtered Air & Normal light in Laminar Air Flow LCD display with soft touch switches for Motor, U.V. Light, F.V. Light & U.V. Timer Automatic motorised front door lifting arrangement Online transfer of data without any cable/wire Interference MICROPROCESSOR BASED TOUCH SCREEN DISPLAY SYSTEM Display of velocity with lower and upper safe limits. Display of total run time of instrument & timer for U.V. lamp Control of U.V. light to prevent the operator from U.V. rays as and when required. Automatic Door sensors to switch off the U.V. light when door is opened. Display of message for life of HEPA filter, U.V. light etc.

Send Message
product image
BIOSAFETY CABINET CLASS III

“OPTICS TECHNOLOGY” Class III Bio safety cabinet offers the highest level of operator, product and environmental protection from infectious/biohazardous aerosols and is suitable for microbiological work. Designed for an absolute level of containment, it is frequently used for work involving the deadliest bio-hazards. A Class III cabinet is defined as a totally enclosed, ventilated cabinet with leak-tight construction it is also called glove boxes. The cabinet is maintained under negative pressure and supply air is drawn in through HEPA filters. A supply of HEPA filtered air provides product protection and prevents cross contamination of samples while exhaust air is HEPA-filtered and incinerated. Key Benefits: Safer dual main with 100% exhaust filters Exclusive dual main exhaust filters provide > 100.000 times better protection than single-stage designs. An integrated pass-through with interlocking doors permits materials transfer without risk of environmental contamination. An angled cabinet front ensures a comfortable working posture. Energy Efficient Blowers Optional: 1. Magnahelic Gauge in place of Static Pressure Manometer. 2. Digital Manometer 3. U.V. Resistant Poly Carbonate sheet in place of Acrylic Sheet. 4. LCD display with soft touch switches for Motor, U.V. Light, F.V. Light & U.V. Timer 5. Imported Gloves 6. Automatic motorised front door lifting arrangement 7. Online transfer of data without any cable/wire Interference MICROPROCESSOR BASED TOUCH SCREEN DISPLAY SYSTEM Display of velocity with lower and upper safe limits. Display of total run time of instrument & timer for U.V. lamp Control of U.V. light to prevent the operator from U.V. rays as and when required. Automatic Door sensors to switch off the U.V. light when door is opened. Display of message for life of HEPA filter, U.V. light etc. With Glove Port (Without Gloves) Outer Body: Wooden / Mild Steel Duly Powder Coated / Stainless Steel (S.S. 304)

Send Message
product image
BIOSAFETY CABINET CLASS II

Applications include isolation and indentification of plant/human pathogens, work in virology, tissue culture, sterility testing and recombinant DNA research. This Biohazard Cabinet offers operator protection from low to moderate risk biological agents (or chemical carcinogens), while providing a sterile work environment for the procedure. The cabinet is kept under negative pressure with partial quantity of recirculated air exhausted through a HEPA filter. External exhaust from the laboratory is optional. The Biological Safety Cabinet is similar in performance and specification to the Vertical Series, described on reserse. The additional main features are as under:- Specially suited for Pathogenic work, chemical work, critical biological work involging virus and pathogens & for microbiology, biochemistry etc. Standard S.S. Perforated table. Imported Mini Pleat HEPA of 0.3 µ of an efficiency of 99.97% down to 0.3 micron Media is of glass fiber & made of pleats back & fro in an anodized aluminum frame (With Test Report). Integral powerful exhaust system. Built-in-positive Air Curtain effect to prevent inside air from going out and room air from entering in, providing total process and operator safety. Exhaust ducting to carry the air outside. Front sliding door, U.V. light, Manometer, Gas cock etc. Mini Pleat HEPA Filter in Exhaust. Virus Burn out Unit in Exhaust. FACE VELOCITY: A face velocity of 90±20 FPM is maintained. Optional: Magnahelic Gauge in place of Static Pressure Manometer. Digital Manometer U.V. Resistant Poly Carbonate sheet in place of Acrylic Sheet. LCD display with soft touch switches for Motor, U.V. Light, F.V. Light & U.V. Timer Gloves Port (Without Gloves) Automatic motorised front door lifting arrangement Online transfer of data without any cable/wire Interference MICROPROCESSOR BASED TOUCH SCREEN DISPLAY SYSTEM Display of velocity with lower and upper safe limits. Display of total run time of instrument & timer for U.V. lamp. Control of U.V. light to prevent the operator from U.V. rays as and when required. Automatic Door sensors to switch off the U.V. light when door is opened. Display of message for life of HEPA filter, U.V. light etc.

Send Message
product image
ICE FLAKING MACHINE

An automatic Ice machine for your hygienic Ice flakes requirement in research laboratories, chemicals, pharmaceuticals, medical, biotechnological and hotel industries. The machine utilizes running tap water and converts it in the form of ice flakes continuously. It is a compact, self contained unit, covering less floor area & easily installable. Constructions: Ice flaker is housed in styled Stainless Steel 304 body with stainless steel made bin with no chances of corrosion. Ice crusher used is GERMAN CRUSHER made of S.S. to give life long performance. Water is introduced into crusher assembly through a precision float valve. The inflow of water is smoothly controlled by this float valve for maintaining a required level of water irrespective of variation in pressure at the water input line with automatic cut off in case of Low water / No water supply. Ice flakes are collected into a well-insulated/ (PUF) stainless steel container. So it stays for longer time. The removal of flakes is easily possible through the stainless steel Top door which can be opened with handle while removing the ice. Moreover the equipment fitted with an ICE LEVEL CONTROLLER which will put off the system in case ice gets accumulated in the container more than the required level. Hence, there is no need of an operator being on the machine all the time. The ice controller is provided with a drain line for occasional cleaning of the container.

Send Message
product image
AUTOCLAVE VERTICAL With Digital Temperature Controller cum Timer

nner chamber is made of thick Stainless Steel (304). Outer body is made of thick Mild Steel / Stainless Steel 304. The chamber is absolutely leak proof and can be operated at any Selected point in between 5 to 20 pounds per sq. Inch. It is provided with pressure gauge, pressure release valve, S.S. Basket, safety valve, water level indicator with cord, Plug & Pressure Control Switch. It is provided with Radial Locking System with Automatic Water Level cut off device for element as a safety feature and Digital Temp. Controller Cum Timer. Temperature Range 121ºC ptional: Vacuum Breaker Valve Calibration Port Safety Alarm Specially designed Lid locking system to make sure lid is locked properly Single channel data logger system (Only with Automatic Model) Printing System with Thermal Printer 21 CFR Software Automatic System (Only for Normal Autoclave Vertical Model) OR Microprocessor Based Automatic Touch Screen Display System with Data Logging

Send Message
product image
DISINTEGRATION TEST APPARATUS (SINGLE / DOUBLE BASKET)

The instrument is designed for accurate estimation of disintegration time of tablets/capsules. It is assembled in painted sheet metal cabinet with chemical resistant epoxy coating, fitted with superior quality constant speed sturdy motor. The guide discs and strokes are confirming to Pharmacopoeia Standards. (Body is made of M.S. Duly Powder Coated / SS 304 Body). Specifications: Displacement : 55mm RPM : 30 Drive : 1/8 HP Heater : 125 watt. Power : 230 V AC Single Phase Optional: Digital Time Totalizer Water bath System Instead of Hot Plate with Thermostatics Temperature Controller Microprocessor Based PID Controller (Only with Water bath model).

Send Message

Still searching for
total run time?